Primary causes seen thus far:

  1. Not reading at all. Re-position switch to where it reads (may need to bend actuator vertically, they are flimsy).

  2. Reads in closed state, but once door close is held it goes out. Re-position switch so it is also active when door close (clutch is picked) button is held.






Run in test:


  1. Pull xbat1

  2. Disconnect 3 phase (wait for controller to die).

  3. Connect 3 phase power.

  4. Plug xbat1 back in.


KDM DCBG Plug Reliability Issues – Field Experience & Feedback

DCBG Plug reliability issues seem to be on the rise again, below I will share faults observed as well as examples of what to look for.

These plugs are very small, take a picture with your phone and zoom in to see crimps.


***PLEASE REMEMBER THAT ORDERING A NEW HARNESS IS NOT A RELIABLE WAY TO RECTIFY FAILURES AS REPLACEMENT CABLE SEEMS TO BE UNRELIABLE.***


XRS1

130-5000-203

131-4000-1

image

XB1

Poor connection On XB1 has caused main brake voltage to reduce well below hold voltage which can lead to 108 faults.



image

XMS1 - 201 Contactor Feedback

Not making up will cause a 268 after 3 consecutive attempts to pick main contactor

****Opening in flight will cause a panic stop but will only cause 187 or 188 and 191 or 192.****


image

Plug Repair - Be cautious not to deform the plastic guides - this will happen if you try to lever your jumper while repairing crimp.

Gently inserting Kone supplied jumper tip between one side of the crimp and the plug should sufficiently squeeze the crimp back together.


image
image




Orientation tit up (viewed from rear/wire side)

pin 4 / pin 3

pin 2 / pin 1

Pinouts:

XBS1 (Main brake);

pin 1 - brown

pin 2 - green

pin 3- unused

pin 4 - white

XBS2 (E-Brake);

pin 1 (PS3+) brown > attaches to red (2)

pin 2 - unused

pin 3 (PS2) yellow > attaches to white (3)

pin 4 (PS1-) white > attaches to green (4)